This report compares distributions of Findings and demographic
variables across treatment
arms.
Note: Refer to
Distribution Reports for a description of the general analysis performed by the JMP Clinical distribution reports.
Running Findings Distribution for
Nicardipine using default settings generates the
Report shown below.
The Report contains the following sections:
Contains Histograms to display the
distribution of Findings tests taken during the study and other relevant
variables for the selected Findings domain.
These display counts and histograms of relevant variables in the Findings data set. A
distribution of subjects on the
Actual,
Planned, or
Specified Treatment is shown as well as other findings variables (if present). Findings variables displayed can include the Findings
Body System (
xxBODSYS),
Reference Range Indicator (
xxNRIND), the
Category for the Test (
xxCAT) and
Subcategory (
xxSCAT), the
Categorical Findings Result (
xxSTRESC, only displayed for categorical findings domains), the
Visit and
Time Points at which findings were taken (
VISIT and
xxTPT),
Baseline Flag (
xxBLFL), and the
Study Day.
The Count Plots section is shown below. This section is shown only when the
xxNRIND variable and either
VISIT or
VISITNUM is found in the Findings data set.
These plots show the distribution of measurements across categories of the
Reference Range Indicator variable (
xxNRIND). For example, you can see how many laboratory measurements for a given test were categorized as
HIGH,
NORMAL, or
LOW based on values of the
Reference Range Upper Limit and
Reference Range Lower Limit (
LBSTNRLO and
LBSTNRHI, respectively). The graph contains bars representing the counts within each category for each treatment across
Study Visits (
VISIT or
VISITNUM).
Contains One-way Analyses ( ANOVA) for each test that has numeric measurement results (
xxSTRESN values), Contingency Analyses for each Findings test that has character results (
xxSTRESC values but missing
xxSTRESN values), or both.
Note: This section can display analyses for numeric and/or categorical findings tests, depending on the tests found within the chosen analysis Findings domain.
It contains one or both of the following elements:
•
|
A set of Oneway Analyses for Numeric Findings Tests.
|
Each analysis represents an Analysis of Variance ( ANOVA) for each numeric Findings test (tests that contain
nonmissing values for
xxSTRESN) to compare measurements taken across different treatment
arms. You can click the
Oneway ANOVA outline box below each plot to show the statistical results of the analysis.
Note that this analysis is across all measurements taken during the study and should be used to get an idea of possibly significant differences in measurements across treatment arms. This is a simple
model. You can fit a more appropriate model that accounts for the repeated measures taken for subjects, as well as initial baseline measurements, with the
Findings ANOVA report.
See the JMP Fit Y by X platform for more details about Oneway Analysis.
•
|
A set of Contingency Analyses for Categorical Findings Tests.
|
See the JMP Fit Y by X platform for more details about Contingency Analysis.
Note: This section is
not shown if all subjects have
nonmissing measurements taken for all Findings tests recorded.
•
|
Show Subjects: Select subjects and click to open the ADSL (or DM if ADSL is unavailable) of selected subjects.
|
•
|
Demographic Counts: Select subjects and click to create a data set of USUBJIDs, which subsets all subsequently run reports to those selected subjects. The currently available filter data set can be applied by selecting Apply Subject Filter in any report dialog.
|
•
|
Click the Options arrow to reopen the completed report dialog used to generate this output.
|
Use the Findings Domain to Analyze option to specify whether to plot the distribution of measurements from either the Electrocardiogram (
EG), Laboratory (
LB), or Vital Signs (
VS) findings domains. LB is selected by default.
You can use the Findings Domain Tests for Analysis option to plot the distributions of one or more selected findings tests. Leaving the field blank (the default selection) plots the distributions for all available findings tests.
Available variables include Planned, which is selected when the treatments patients received exactly match what was planned and
Actual, which is selected when treatment deviates from what was planned.
You can also specify a variable other than the ARM or
TRTxxP (planned treatment) or
ACTARM or
TRTxxA (actual treatment) from the CDISC models as a surrogate variable to serve as a comparator. Finally, you can select
None to plot the data without segregating it by a treatment variable.
Selecting LLN normalizes the data to the lower limit of the expected normal range and is best used when you expect the values to fall below the normal. Normalized values less than one are considered to be lower than normal.
Selecting ULN normalizes the data to the upper limit of the expected normal range and is best used when you expect the values to exceed the normal range. Normalized values greater than one are considered to be higher than normal.
Selecting Geometric normalizes the data such that the lower limit of the expected normal range is set to -1 and the upper limit of the expected normal range is set to +1. This method is best used when there is no expectations of where the values might fall. Normalized values less than -1 are considered to be lower than normal while values greater that +1 are higher than normal.
Note: These options are available only when
LB is the specified domain.
If there is a supplemental domain (SUPPXX) associated with your study, you can opt to merge the non-standard data contained therein into your data.
The Subset of Visits to Analyze option enables you to restrict to a specific subset of visits.
Check the Perform Oneway or Contingency Analysis option to perform a one-way analysis for continuous tests or a contingency analysis for categorical/character tests.
Use the Variables to include in Report Filter option to specify the variables to be included in the report data filter.