This section defines positive and negative shift detection for the CUSUM Chart.
A positive shift occurs when the value of C+ exceeds the upper limit on the chart. The start of the shift is defined as the first point after the most recent zero value for C+.
A negative shift occurs when the value of C- exceeds the lower limit on the chart. The start of the shift is defined as the first point after the most recent zero value for C-.