For the latest version of JMP Help, visit JMP.com/help.


Publication date: 11/29/2021

Create Design Tables

Use the buttons to make the accelerated lift test design, test plan, and table.

Make Design

Updates the optimal design if any changes are made to the Distribution Choice, Prior Mean, Prior Variance Matrix, Design Choices, or Candidate Runs.

Make Test Plan

Creates a data table where each row corresponds to a distinct design setting. The table shows the acceleration factor design settings and the number of units to test at those design settings.

Make Table

Creates a table that you can use for recording your failure time data.

For Continuous Monitoring, the table contains a row for each unit to be tested and the design settings for that unit. If a unit fails during the experiment, record the unit’s failure time in the Failure Time column and a 0 in the Censored column. If a unit does not fails during the experiment, record the final inspection time in the Failure Time column and a 1 in the Censored column.

For Monitoring at Intervals, the table contains a row for each design setting and time interval combination. The time intervals are defined by the Start Time and End Time columns, which are based on the Inspection Times entered in the Design Choices outline. For each setting and time interval, record the number of units that failed in the Number Failing column.

Want more information? Have questions? Get answers in the JMP User Community (community.jmp.com).